Laemmli sample buffer for SDS PAGE (2X)
126 mM TRIS/HCl (pH 6,8)
20% Glycerol
4 % SDS
0,02 % Bromophenol Blue

- Prepare a stock solution 1M TRIS/HCl (pH 6,8) first. Therefore, weigh 121,1 g TRIS, transfer it to a 1L beaker and solve it with 800 ml deionised water. Adjust the pH value to 6,8 with concentrated hydrochloric acid and fill up to one liter with deionised water.
- Then fill the beaker up to the 1L mark with deionised water.
- Give it another short stirr and fill it into a screw cap bottle.
- For 100 ml 2X Laemmli sample buffer fill 12,6 ml of the 1M TRIS/HCl (pH 6,8) stock, 20 g Glycerol, 4 g SDS und 20 mg Bromophenol Blue into a beaker, fill up to 80 ml with deionised water and stirr until the chemicals are completely solved.
- Then fill the beaker up to the 100ml mark with deionised water.
- Give it another short stirr and aliquot.

- Mix 100ml Laemmli running buffer 10X with 900ml deionised water.
- Fill your SDS PAGE chamber with it.

- Mix Laemmli running buffer 2X with the same amount of sample.
- Denature sample 5 minutes at 95°C.
- Load sample on gel.